POWERSCAN™ D8330/M8300
156
5.6 READING PARAMETERS
5.6.1 Trigger Signal
This mode determines how the reading phase is controlled when the hardware trigger
operating mode is selected:
trigger active level: the reader goes ON when the trigger is pressed and goes OFF
when it is released
trigger active pulse: the reader goes ON at the first trigger press and goes OFF
only at a second press
5.6.2 Trigger Click
When enabled, it activates a "click" sound upon each trigger pressure.
5.6.3 Trigger-Off Timeout
When this timeout is selected, the reader turns OFF automatically after the desired
period of time.
5.6.4 Reads per Cycle
In general, a reading cycle corresponds to the ON + OFF times of a device.
The resulting effects of this parameter on code reading depend on other related
configuration conditions. Here are the definitions of ON and OFF times.
For readers using the software trigger parameter (FLASH MODE), a reading cycle
corresponds to the
flash on
+
flash off
times. Code reading takes place during the
flash on
time.
For readers using the
hardware trigger
parameter, a reading cycle corresponds
to a trigger press (ON) + one of the following OFF events:
trigger release (for
trigger active level
)
a second trigger press (for
trigger active pulse
)
trigger-off timeout
(see section 5.6.3).
When one read per cycle is selected, the device decodes only one code during the ON
period and immediately turns the reader OFF. It is only possible to read another code
when the next ON time occurs.
Comentários a estes Manuais